Hired-hand RollSeal Rollup Curtains: RollSeal Motor Controls Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
4801-5146 Rev 2-08 Motor Controls Page 12
7.10 Connecting Motor Control to Curtain Control
7.11 Connecting Motor Control to Farm Hand 4-Stage
Control or Swine Finisher
1
Motor Control
Note: Connecting multiple Motor Controls
t
o one control source parallel output, open
and close connections as shown for each
additional controller.
Multiple Motor Control
To
Cont
r
olle
r
To
Controlle
r
To
Unit 1
To
Unit 2
1
GND
65432
L1
L2
24
V
OPEN
CLOSE
CONTROL
POWER
240
V
1
GND
65432
L1 L2
24V
OPEN
CLOSE
CONTROL
POWER
240
V
COM
OPEN
CLOSE
COM
OPEN
CLOSE
COM
OPEN
CLOSE
COM
OPEN
CLOSE
Warning!
All Controllers Must Also Have The Same Power
Supply Connected In Parallel To L1 & L2 &/or L3.
Warning!
All Controllers Must Also Have The Same Power
Supply Connected In Parallel To L1 & L2 &/or L3.